Description | Value |
---|---|
Voltage Rating (Uo/U): | 300/500 Vac |
Test Voltage: | 2500 Vac |
Temperature Range (Inner Insulation Only): | -55 °C ÷ 180 °C |
Temperature Range (Outer Insulation Only): | -20 °C ÷ 105 °C |
Short Circuit Temperature: | 160 °C |
Minimum Bending Radius: | 14 x Overall Diameter |
Conductor Size: | 3 x 0.75 mm2 |
Conductor Stranding: | 19 x 0.224 mm |
Electrical Resistance : | ≤ 26.7 [Ω/km] |
Insulation Thickness: | ≥0.60 mm |
Outer Diameter: | 5.6 ± 0.2 mm |
Product Code: | BTPF-403 |
Cable Standards:
Low Voltage European Directive No. 2014/35/UE.
Stranding of Conductor:
Electrolytic tinned flexible concentric rope copper conductor.
Inner Insulation:
R5F type FEP conforming to EN-50363-0 requirements.
Outer Insulation:
Transparent 105 °C PVC, hardness: [87 + 2] Sh-A.
Cable Assembly:
The cores are braided in viscose rayon before being twisted together.
Core Identification:
3 Core: Brown, Blue and Green/Yellow